Mcquay model number tonnage.

Monday, August 23, 2021. The first letter of the serial number denotes the year of manufacture for First Co. products, based on the listing below. The serial number may be noted on two lines, as below, or one line. So "I" indicates 2002 manufacture. A = 1994 B = 1995 C = 1996 D = 1997 E = 1998. F = 1999.

Mcquay model number tonnage. Things To Know About Mcquay model number tonnage.

Part Number: 331374601 Effective: March 2008 Supersedes: December 2007 Water-Cooled Centrifugal Chiller ... The McQuay Model WMC Centrifugal Water Chillers are complete, self-contained, automatically controlled, fluid-chilling units featuring oil-free, magnetic bearing compressors. Each unit is completely assembled and SALES Hunter: 713-851-7576 Jamey: 214-755-8019 . Para Español: 214-321-4200 1998 McQuay Air Cooled Liquid Chiller- 204 Ton. Model: ALS204AS12. S/N: 58G8128101. Refrigerant: R-22. Maximum relief pressure: 450 psig. Design pressure hi/lo: 450/150 psig. System requirements: 208 V, 881 amps, 60 Hz, 3 phase. (2) McQuay Screw Compressors, Models: SAL175RA13DA and SA175BA13DA, S/N's: 52ER7027-10 andMODEL NUMBER IDENTIFICATION GUIDE 300 360 Sales Code GAS HEATING OPTIONS (BTUH) 360 = 360,000 275 = 275,000 ... COOLING CAPACITY (NOMINAL BTUH) 300 = 25 Ton MODEL NUMBER PRODUCT FAMILY Package Units TYPE Heat Pump A = Air Conditioner DESIGN SERIES Standard Efficiency Gas/Electric . Title: ICP Product Identification Guide Author: ICP at ...Part Number: 668996503. Date: November 2011. IM 930-3 ©2011 McQuay International ® Page 2 of 32 / IM 930-3. Model Nomenclature Vertical Floor Unit (Size *007 - 070) NOTE: For illustration purposes only. Not all options available with all models. Please consult McQuay Sales Representative for specific availability.

1947 Ford Models - The 1947 Ford models were little changed from 1946, and not all the changes were good. Learn more about the 1947 Ford models. Advertisement The factory-suggested...McQuay Water Chiller. Model ALR195C-X. Approximate capacity: 195 nominal tons using R-22 based on conditions of 95°F ambient air and a 10°TD change between 55°F and 45°F. Test pressure hi/lo: 380/150 psig. Max relief pressure: 450 psig. (4) 8-cylinder compressors, 60 Hp each 460V 60 Hz 3 phase. (14), 26 in. dia. fans and motors: 1hp, 460V ...The cooling and gas heating units with bottom duct connections, model EPGDA, are available in four cooling capacities: 2, 3, 4 and·5 tons. In ad­ dition, the EPGDA units are available with a 1 horsepower belt drive supply fan/motor assembly for higher static pressure applications on 3, 4 and 5 ton, 3-phase units.

oneSOURCE Document Management Services; RLDatix Corporate Office 311 South Wacker Drive Chicago, IL 60606; PO Box 581230 Salt Lake City, UT 84158-1230

McQuay Horizontal Water Source Heat Pump - 1/2 to 6 Ton - Free download as PDF File (.pdf), Text File (.txt) or read online for free.The McQuay cabinet unit heater combines all the time proven quality features of McQuay units with a solid-state speed controller and a modern decorator styled cabinet to meet today's ever-increasing demands for attractive appearance, quiet performance, proven reliability and individual comfortThe Skyline® air handling unit is designed to meet or exceed these demands. In addition to our patented construction, it features a durable, weathertight cabinet that promotes long life of your air handler. Skyline® also combats air contamination with micro-filtration, bacteria-defeating UV lights, mold-resistant drain pans, and anti ...McQuay compressors are used for a wide range including Refrigeration, Air Conditioning and Heat Pump applications. Benefits of choosing Mcquay compressors: ... Company Number: 04147637. Registered Office: Unit 10, Dunston Innovation Centre, Dunston Road, Chesterfield, ...

Daikin Applied RoofPak® RPS (15-140 Tons) Design flexibility, energy efficiency, system performance and reliability make Daikin RoofPak® applied rooftop systems the ideal solution for your one to eight-story building projects. Available in air-cooled and evaporative-cooled models, with capacities from 15 to 150 tons, they combine the lower ...

McQuay Unit how many tons. Good afternoon everyone. Attached is a photo of a unit nameplate. Can anyone tell me how many tons of cooling this is? I am guessing it does not do any heating. Model #MPS050AE4DV1CYBV. Serial #FBOU081001739. Would you call this a self contained unit or a dx unit? Thanks. Reply. 07-27-2012, 08:31 PM #2.

GROUP mcQUAY..P&Af'EX Inc. t36001ndustriaiParkB!vd.P.O.Box1551,Minneapolis,Mn.55440 . ND ... Available in three model types for horizontal and vertical unit arrangements: LSL VERTICAL UNIT ... -----NUMBER OF FANS IN STANDARD UNIT LYF-VENTILATING FAN SECTION LHD -HEATING AND VENTILATING UNITManufacturer McQuay. Tonnage 500. Air or Water Water Cooled. Refrigerant R-134a. Voltage 460. Phase 3. Hz 60. Model Number WME0501SBSNA. Serial Number STNU180500021.Our Technical Support Department staff may be reached at 1-800-828-5500, Monday thru Sunday from 8:00 a.m. to 10:00 p.m. EST. The technicians there will ask you a number of questions while researching our historical manufacturing archives in an effort to determine the model number and manufacturing data of the product.We are installing a McQuay Model AGZ029B NOMINAL 29-TON AIR-COOLED CHILLER UNIT on my project here @ Eglin AFB, FL. I have to install the pad for this unit, and my contract drawings state to build as per the manufacturer's recommendation.The Skyline® air handling unit is designed to meet or exceed these demands. In addition to our patented construction, it features a durable, weathertight cabinet that promotes long life of your air handler. Skyline® also combats air contamination with micro-filtration, bacteria-defeating UV lights, mold-resistant drain pans, and anti ...McQuay Cat 251-1 5. Maverick I™—3 to 20 Tons [10.6 to 70.3 kW] Scroll compressors. • R-22 refrigerant • Provide maximum depend ability, efficiency and quiet operation. • Two refrigerant circuits on larger units provides redundancy for reliable cooling • Optional compressor low and high pressure safety switches.

ner on the main control box door. It includes the unit model number, serial number, unit part number, electrical character-istics, and refrigerant charge. Compressor Nameplate On units with a single compressor on each circuit, the com-pressor will include one compressor nameplate. On units that utilize the tandem compressor design, eachBasically all manufacturers encode the size or tonnage of their systems into the model number. Tonnage is a measure of BTU's in 12,000 BTU increments. For example a 1 ton system would have 12,000 BTU's. A 2.5 ton system would have 30,000 BTU's. These are reflected in the model numbers near the middle and often followed by a letter.Here's a rundown of the range you will encounter: 18 = 1.5 tons, 24 = 2 tons, 30 - 2.5 tons, 36 = 3 tons, 42 = 3.5 tons, 48 = 4 tons, and 60 = 5 tons. And this is another one for a 3 ton system. If you are unsure whether you have found the right two numbers, you can double-check it by looking for the "RLA" rating on the data plate.The units have automatic control of the condenser fans which should provide adequate head pressure control down to: 50°F (10°C) as standard. 0°F (-17°C) with option (see “Optional Low Ambient Compressor Operation” on page 16) …The tonnage of an AC unit can typically be determined from the model number by looking for a number that is divisible by 12. For example, if the model number is ABC12345, and the number 36 appears in the middle of the model number (e.g., ABC36 12345), then the AC unit is likely a 3-ton unit, since 36 is divisible by 12.Model Line. Model Line 10 Easy Maintenance Tips. View Resource . A Parts Map - CXVB Evaporative Condenser. View Resource . A Parts Map - FXV Closed Circuit Cooling Tower ... The serial number will be spray painted on your unit and/or on a label by the access door. For units purchased after 2000 it will start with a U. Model Number.

the last digit in the model number following the "D" vintage designation (i.e. AGS 220DS or AGS 220DM) are designed to meet ASHRAE 90.1 efficiency standard. These units provide the lowest dollar per ton price. Ratings begin on page 18. High Efficiency, designated by an "E" (or "F" with remote evaporator) as the lastDaikin RoofPak applied packaged rooftop systems, from 15 to 150 tons, are the ideal solution for your one to eight-story building projects. Available in air-cooled and evaporative-cooled models, they combine the lower installation costs and interior space savings of a roof-mounted system with the operating and maintenance efficiencies of ...

Find Us. McQuay Air-conditioning Limited (+852) 2893 6261; Unit 901~905, 9/F,Elite Centre, 22 Hung To Road, Kwun Tong, Kowloon,Hong KongMcQuay Water Source Heat Pumps. In 2009 we added McQuay Water Source Heat Pump units to our product line. We handle Horizontal, Vertical, and Console units up to 72000 BTU. Over 40 years ago McQuay introduced a complete line of water source heat pumps. WSHP units are used in schools, hospitals, office buildings, hotels, and many other applications.ALP 012D through 019D. IM 687. Install the unit with three feet of side clearance for air entrance to the coil and for servicing. Provide four feet of service access at each end to access the evaporator, compressors, electrical control panel and piping components. Do not allow debris to accumulate near the unit.5 Tons = 60,000 BTU = 3,000 sq. feet (Model: RACCZR060) You can also manually compute the AC size based on the measurement of the area to be cooled. On average you'll need 0.0016 tons of AC per square foot. For instance, your house is 600 square feet. Multiply 600 by 25 BTU, and the product is 15,000.Hippocratic, a startup creating a language model specifically for healthcare use cases, has launched out of stealth with $50 million in seed funding. AI, specifically generative AI...We have done the research to provide you with the details about the tonnage of a Goodman air conditioner. You can determine the tonnage of your Goodman air conditioning by dividing the BTU by 12,000. If the information about the BTU is not available, you can check the model number. You will find 0 and two-digit even numbers ranging from 18 to 60.1994 McQuay Water-Cooled Chiller- 320 Ton. Model: PEH079. S/N: 5ZE81006-00. Style: 9572513010. Liquid chiller; self-contained unit. R-134a only. Compressor hours: 9812; compressor starts: 1814. Overall dimensions for chiller: 234.5 in. L x 46 in. W x 72 in. H. This unit was the East Campus Chiller running two dorms atWhen you need OEM parts or generic parts to repair your HVAC system, you need them quickly. Daikin Service has an expansive inventory and a centralized distribution center to get the right parts to you faster than ever before. To mitigate downtime, we have 80 locations (and counting) across North America and Canada to help you take care of your ...A ton of air conditioning equals 12,000 BTU, and 24 divided by 12 equals 2, so the data plate below indicates the system is 2 tons. Here's a rundown of the range you will encounter: 18 = 1.5 tons, 24 = 2 tons, 30 - 2.5 tons, 36 = 3 tons, 42 = 3.5 tons, 48 = 4 tons, and 60 = 5 tons. If you are unsure whether you have found the right two ...McQuay Type WGS water chillers are designed for indoor installations and are available with factory-mounted water-cooled condensers (Model WGS AW), or arranged for use with remote air-cooled or evaporative condensers (Model WGS AA). Each water-cooled unit is completely assembled and factory wired before evacuation, charging and testing. They

Today, McQuay possesses more than 13 manufacturing plants occupying some 200,000 square meters on three continents; North America, Europe and Asia together with sales and service offices in 75 countries. With a diligent workforce of over 15,000, McQuay is dedicated to producing the best quality equipment in the air conditioning industry.

Model: The Unit Model Number: Note- It is very important to remember that the AAF and HermanNelson model numbers differ from all the other brand names listed in the index in that the model number is located in the middle of the alpha/numeric model number string. (Example: SPAGAAPFCWG53211000. The bold letters indicate the model number.

Model: The Unit Model Number: Note- It is very important to remember that the AAF and HermanNelson model numbers differ from all the other brand names listed in the index in that the model number is located in the middle of the alpha/numeric model number string. (Example: SPAGAAPFCWG53211000. The bold letters indicate the model number.Trying to find out about age and tonnage of an old Singer air conditioner condensing unit. I understand that McQuay acquired Singer back 20 years ago or so. The model is ACR 51048-1A F and the Serial is(###) ###-####E11-0070. I am needing to replace four of these units and it would be a great help to know their size. Thanks! Pete(2 to 5 Ton) Bulletin #490034 ... CHA16H-261 model requires 2 per unit, LB-82199CH (47J25). CHA16-413 model requires 2 per unit, LB-82199CF (47J23). CHA16-513-653 models require 3 per unit, LB-82199CG (47J24). Correct number of guards are furnished per order number. Compressor Crankcase Heater (Optional for CHA16H-261 Model ...McQuay Air Cooled Chiller 130 Ton Model: ALR130BD Stock No. ACEU07 Serial No. 3NB0014312 . McQuay Air Cooled Chiller 130 Ton. Model ALR130BD. S/N 3NB0014312. Barrels were replaced in . 1993 with newer models. Model CDE1410, S/N 5YM0015300. ... Document Number: PM ALR2-4. Revision: Replaces: April 2001. PM ALR2-3A one-ton AC can remove 12,000 BTUs of air per hour, a two-ton AC can remove 24,000 BTUs, and so on. To put it simply, the higher the AC tonnage the more air it can cool. Why Knowing Your AC Tonnage Is Important. Now you might think that you need to buy the highest tonnage to get maximum cooling power and efficiency.Chiller package includes (4) scroll Copeland mnfg compressors, air-cooled condenser, shell/tube heat exchanger and starter box with related electrical all mounted in an outdoor cabinet. Chiller Model: AGZ065AS4242-ER10-ER, SER#STNU990700115. Unit dimensions: 7'6"x 8' x 8'H. +42 to +60 setpoint. Unit designed to operate on refrigerant R-22 or equal.Find Us. McQuay Air-conditioning Limited (+852) 2893 6261; Unit 901~905, 9/F,Elite Centre, 22 Hung To Road, Kwun Tong, Kowloon,Hong Kong2005 McQuay Air Cooled Water Chiller- 25 Ton. Model: AGZ025AS27-ER11. SN: STNUENG082905. ... Copeland Scroll Compressors, Model: 2R16M3-TWD-570, S/N's: 00K66752G and 99195362G, 3,500/2,900 rpm, 460/380-420 . 2005 McQuay Air Cooled Water Chiller- 25 Ton. Model: AGZ025AS27-ER11. SN: STNUENG082905. ... Serial Number: STNUENG082905; Chiller Details ...Daikin RoofPak applied packaged rooftop systems, from 15 to 150 tons, are the ideal solution for your one to eight-story building projects. Available in air-cooled and evaporative-cooled models, they combine the lower installation costs and interior space savings of a roof-mounted system with the operating and maintenance efficiencies of ...Air handling units 3 Air flow (m /h x 1,000) 0 20 40 50 60 70 80 90 100 120 140 D-AHU Professional 750 m3/h up to 144,000 m3/h Modular P › Pre-configured sizes › Plug and play concept › EC Fan technology

McQuay Water Cooled Chiller, year 1988, Model WHR070D, S/N 5TD0189100, 460 volt, 70 ton, 2 compressors.When it comes to finding the perfect microwave for your kitchen, GE is a brand that stands out. With its wide range of models and features, there’s a GE microwave model number to s...Evaporator Model Number CE 063 J AY 18 R Motor HP (X10) Impeller Type: J or K Impeller Size:060= 6.0" 063= 6.3" Gear Ratio (see Gears table for list) Compressor Model Number Compressor Type: CE= Centrifugal Hermetic PE 200 Unit Model Number Unit Type: PE- a single compressor, hermetic centrifugal chiller. Nominal Tonnage Unit Voltage N=200/60/3 ...Instagram:https://instagram. blox fruit trading valuesjimmy john's summer wraps nutritionhusky tool cabinet partsgift card exchange coinstar near me ner on the main control box door. It includes the unit model number, serial number, unit part number, electrical character-istics, and refrigerant charge. Compressor Nameplate … crime rate mesa azearly 2000s drinks 60Hz SEER10 R410A Cooling Only. Notes: The cooling condition: T1 condition: indoor side 27°C (80.6°F) DB, 19°C (60°F) WB, outdoor side 35°C (95°F) DB; The heating condition: indoor side 20°C (68°F) DB, 15°C (44.6°F) WB, outdoor side 7°C (42.8°F) DB. Sound level: measured at a point 1m in front of the unit at a height of 1.3m. meijer gift card selection a solution for your specific application. Contact your local McQuay sales office for computer selections of chillers to match your requirements. The following chart provides recommendations for the model choice for your application. Application McQuay Model Cooling, most hours at full load WSC – Single compressor chiller Models AGZ-E, AGZ-F, AMZ, EWYQ. Cool your building more efficiently and save money with the Trailblazer air-cooled scroll chiller. The Trailblazer is Daikin Applied's first available unit designed with R32 refrigerant, boasting a 33% reduced footprint and 10% reduced weight. Trailblazer chillers operate in off-design conditions 95% of the ... R = 208-230/1/60 62 = 5 Vintage * 10 SEER Size 036, 049 and 060 only. **10 SEER Size 060 only. Table 1: Unit Nameplate Model Number Identifier Unit Nameplate McQuay Model Number CKL18-1L ACU018ARAY CKL24-1L ACU024ARAY CKL30-1L ACU030ARAY CKL36-1L... Page 4: Introduction Replacement Parts substantial fines.